Description
| DN5600 Application | Relay Mode |
![]() |
![]() |
| General Specification | |
| Input Sensitivity | 0.2㎶ / Digit |
| Load Cell Excitation | DC 10V ( – 5V ~ + 5V ) |
| Max. Signal Input Voltage | Max.32mV |
| Temperature Coefficient | [Zero] ±20PPM/℃ / [Span] ±20PPM/℃ |
| Input Noise | ±0.6㎶ P.P |
| Input Impedance | Over 10㏁ |
| A/D Conversion Method | Sigma-Delta |
| A/D Resolution(Internal) | 520,000 Count(19bit) |
| A/D Sampling Rate | Max. 200times / Sec |
| Non-Linearity | 0.01% FS |
| Display Resolution(External) | 1/30,000 |
| Display Part | ||
| Display | Parts | Specification |
| Display | Main Display | 7Segments, 6 Digit RED FND Display |
| Size :20.0mm(H)×13 mm(W) | ||
| Min. Division | ×1, ×2, ×5, ×10, ×20, ×50 | |
| Max. display value | 999,950 | |
| Under Zero value | “-” (Minus display) | |
| Status lamp | Steady, Zero, Tare, SP1. SP2, SP3, SP4, RTxD | Green color Condition display Lamp (8pcs) |
| K e y | Number, Function Key | Number Key, Function (16pcs) |
| – Option | |
| Option No.1 | 0~10V (Analogue Output) |
| Option No.2 | 4~20mA (Analogue Output) |
| Option No.3 | RS422/485(Serial interface) |
| Option No.4 | BCD Input |
| Option No.5 | BCD Output |
※ Serial Interface (RS-232C) or Current Loop is Standard installed with 1 port.